HEIDENHAIN iTNC 530 (340 49x-06) Cycle programming User Manual
Page 391
HEIDENHAIN iTNC 530
391
15.13 D
A
TUM IN ONE AXIS (C
y
c
le
41
9, DIN/ISO: G41
9
)
2 TCH PROBE 413 DATUM OUTSIDE CIRCLE
Q321=+25
;CENTER IN 1ST AXIS
Center of circle: X coordinate
Q322=+25
;CENTER IN 2ND AXIS
Center of circle: Y coordinate
Q262=30
;NOMINAL DIAMETER
Circle diameter
Q325=+90
;STARTING ANGLE
Polar coordinate angle for 1st touch point
Q247=+45
;STEPPING ANGLE
Stepping angle for calculating the starting points 2 to 4
Q261=-5
;MEASURING HEIGHT
Coordinate in the touch probe axis in which the measurement is
made
Q320=2
;SETUP CLEARANCE
Safety clearance in addition to MP6140
Q260=+10
;CLEARANCE HEIGHT
Height in the touch probe axis at which the probe can traverse
without collision
Q301=0
;MOVE TO CLEARANCE
Do not move to clearance height between measuring points
Q305=0
;NO. IN TABLE
Set display
Q331=+0
;DATUM
Set the display in X to 0
Q332=+10
;DATUM
Set the display in Y to 10
Q303=+0
;MEAS. VALUE TRANSFER
Without function, since display is to be set
Q381=1
;PROBE IN TS AXIS
Also set datum in the touch probe axis
Q382=+25
;1ST CO. FOR TS AXIS
X coordinate of touch point
Q383=+25
;2ND CO. FOR TS AXIS
Y coordinate of touch point
Q384=+25
;3RD CO. FOR TS AXIS
Z coordinate of touch point
Q333=+0
;DATUM
Set the display in Z to 0
Q423=4
;NO. OF MEAS. POINTS
Number of measuring points
Q365=1
;TYPE OF TRAVERSE
Position on circular arc or linearly to the next touch point
3 CALL PGM 35K47
Part program call
4 END PGM CYC413 MM