Choice of number of measuring points – HEIDENHAIN iTNC 530 (340 49x-06) Cycle programming User Manual
Page 470

470
Touch Probe Cycles: Automatic Kinematics Measurement
1
8
.4 MEA
S
URE KINEMA
TICS (Cy
c
le 451, DIN/ISO: G451; Option)
Choice of number of measuring points
To save time you can make a rough optimization with a small number 
of measuring points (1-2).
You then make a fine optimization with a medium number of 
measuring points (recommended value = 4). Higher numbers of 
measuring points do not usually improve the results. Ideally, you 
should distribute the measuring points evenly over the tilting range of 
the axis. 
This is why you should measure an axis with a tilting range of 0° - 360° 
at 3 measuring points at 90°, 180° and 270°.
If you want to check the accuracy accordingly, you can enter a higher 
number of measuring points in the Check mode.
Choice of the calibration sphere position on the 
machine table
In principle, you can fix the calibration sphere to any accessible 
position to the machine table and also on chucking equipment or 
workpieces. The following factors can positively influence the result of 
measurement:
On machines with rotary tables/tilting tables:
Clamp the calibration sphere as far as possible away from the center 
of rotation.
Machines with large traverse:
Clamp the calibration sphere as closely as possible to the position 
intended for subsequent machining. 
You must not define a measuring point at 0° or 360°. 
These positions do not provide any metrologically relevant 
data and lead to an error message!