beautypg.com

Grass Valley T-POV Bidirectional Robotic User Manual

Page 48

background image

42

T-POV 324 Components

T-POV 324 Powered Unit Detail

Green: high voltage is being supplied to the camera.

Off when there is no high voltage applied to the camera

CABLE OPEN: indicates that the high voltage cable is open or there is no high

voltage cable connected.

Green: the cable is properly connected from the Base Station to the camera.

Red: there no cable connected to the camera, or the cable is connected but

open.

High voltage will not be applied to the camera until the open condition is
corrected.

CABLE SHORT: indicates that the high voltage cable connected is shorted.

3: STATUS INDICATORS

BASE POWER: indicates the status of all power levels in the Base Station

Green: all power levels are normal.

Red: any power level is not normal.

SYSTEM LOCK: indicates that the Base Station is communicating with the Camera

Unit.

Green: Base Station is communicating with Camera Unit.

Red: Base Station is not communicating with the Camera Unit.

FIBER LINK: indicates the optical power status of the Base Station and camera

Green: both the Base Station and camera optical power are within a normal

range.

Red: both the Base Station and camera optical power are not within a normal

range

Amber: either the Base Station or camera optical power are not within a

normal range.

ALARM: indicator will light Red if there is a temperature, power, hardware or

firmware fault in the base unit system. The indicator will light Amber if there is a
fault at the Camera Unit.

Red: there is a Base Station error. Refer to the Base Station DIAG for details on

the error.

Amber: there is a camera error. Refer to CAM DIAG for details for the error.