T-pov 324 multiple unit detail, Area a area b – Grass Valley T-POV Bidirectional Robotic User Manual
Page 46

40
T-POV 324 Components
T-POV 324 Multiple Unit Detail
T-POV 324 Multiple Unit Detail
The T-POV 324 Multiple Unit Base Station differs from the single unit model in that there are
additional LED indicator columns in Area A. Component operation differences are noted
below.
Fig. 4-6: T-POV 324 Multiple Unit
AREA A
The indicator AREA A in the two unit Base Station operates identically to that of a single unit
model (see
Area A - Signal Indicator LEDs
on page 37). The indicator LEDs monitor their
functions independently of each other.
AREA B
Fig. 4-7: T-POV 324 Multiple Unit Detail -- Area B
SELECT button (1) chooses between three modes of operation and between two or three
camera units, depending on how many camera units are installed in the base station
When the Base Station is powered on, Base Station optical power is displayed.
• The first push of the select button will select CAM 1.
• The second push will select BASE 1.
• The third push will select CAM 2.
• The fourth push will select BASE 2.
• Pushing and holding the SELECT button will enter the diagnostics mode for the device
currently being displayed.