Chapter 11 Field Replaceable Units (FRUs)

168

Digital News Production

5. Power on the storage subsystem. Both controllers will now start up and go

through a number of self tests. At the end of the test, both controllers blink
the third LED on the controller at a one-second intervals. If this does not
happen after five minutes, power-cycle the storage device again.

6. Power on both nodes once the storage subsystem has the blinking lights.

7. Start GUI and verify replacement was successful.