Chapter 11: field replaceable units (frus), Chapter 11, Field replaceable units (frus) – Grass Valley Network Attached Storage System Serial ATA Network User Guide v.1.0.04 User Manual
Page 156

Digital News Production
155
Chapter
11
Field Replaceable Units (FRUs)
NewsShare NAS is a high-availability system, which means that if one
component of a system fails, the partner component keeps the system running.
However, it is crucial that you replace a failed part as soon as possible. To order
replacement parts, go to http://www.ciprico.com/csHome.shtml.
The following components are Field Replaceable Units (FRUs):
• Server node
• Drive
• Power supply in the array
• Array fan
• RAID controller
Most FRUs are hot-swapable (which means that they can be replaced while the
NewsShare NAS system is powered up and running); the exception is the RAID
controller.
>>> The RAID controller cannot be replaced while NewsShare NAS is powered up
and running. To replace a RAID controller, power down the system.
>>> Before replacing any part of the system, back up all data.
NewsShare NAS notifies you of the failure of a component in one or more of
the following ways:
• If you set up SNMP (refer to page 53) and SMTP (refer to page 54)
• Status light on the component
• Via the NewsShare NAS software status bar. If a component fails, the Status
bar displays a status of “Degraded” or “Warning”.