Disk enclosure information – Grass Valley Network Attached Storage System Serial ATA Network User Guide v.1.0.04 User Manual
Page 131

Chapter 10 RAID System Administration
130
Digital News Production
Disk Enclosure Information
To view enclosure information, click on a controller icon in the RAID
Logical/Physical View window. The Disk Enclosure window appears. The
enclosure number is written on the back side of the physical enclosure.
The Disk Enclosure window describes the fields for an enclosure:
ASC
Should always be a blank.
ASCQ
Should be a blank, if the drive is Ready. If it is not a blank, refer to
the PFR-600 User and Service Guide (21021880) to interpret the
code. Or, if the code relates to a drive problem, refer to the drive
manufacturer’s reference manual.
Extra Sense Data
Should be a blank, if the drive is Ready. If it is not a blank, call
Ciprico Customer Support for help in interpreting the code.
Field
Description
Midplane Revision Level
The hardware revision of the midplane.
Left/right Temperature
Sensor
The current temperature in degrees Celsius and the State. State can
be:
• OK: The current temperature is below the warning temperature
setting.
• Over Warning Temperature: The current temperature is at or
above the warning temperature setting and below the critical
temperature setting.
• Over Critical Temperature: The current temperature is at or
above the critical temperature setting.