JEP Series — Installation Manual

71

Salvo Switching

Note

The JEP-100 Salvo function requires Jupiter version 7.4 software (or newer)
to be operating in the CM-4000.

The

SALVO

key can be used to execute a list of pre-built Jupiter sequences,

where a sequence is a switch of one or more sources to one or more destina-
tions.

Setting Up a Sequence

A Jupiter sequence is built using the Jupiter Sequence Set table, an
example of which is shown

Figure 36. Example of Jupiter Sequence Set table

The sequence set is given an eight-character (max) name and is of type
"3800."

In this example, sequence set "SETUP" contain two sequences: "SET UP1"
and "SETUP2." "SETUP1" will switch Cameras 1 through 3 into Monitors 1
through 3 (a total of three switches) with a single TAKE command.
"SETUP2" will reverse the order of the cameras in the monitors. Each
sequence can include up to 25 events (switches).

There is no specific limit to the number of sequences, but due to memory
restrictions a limit of 16 is recommended (e.g., "SETUP1" through
"SETUP16."

The sequence set must be assigned to the JEP-100 panel on the Jupiter MPK
Devices

table.

For additional information regarding Jupiter sequences and assigning
them to control panels, refer to the CM-4000 or CM-4400 manual.

1

Sequence Set - SETUP

Sequence

SETUP1

Input

CAM1

Levels

YYYY

2

3

4

SETUP1

CAM2

YYYY

SETUP1

CAM3

YYYY

SETUP2

CAM1

YYYY

Output

MON1

MON2

MON3

MON3

...

...

...

...

Logical

Logical

5

6

SETUP2

CAM2

YYYY

SETUP2

CAM3

YYYY

MON2

MON1

...

...

071_

8

536_02_seq-ta

b

le