Salvo switching, Setting up a sequence, Jep series — installation manual 71 – Grass Valley JEP Series v.1.3.0 User Manual
Page 71

JEP Series — Installation Manual
71
Salvo Switching
Note
The JEP-100 Salvo function requires Jupiter version 7.4 software (or newer)
to be operating in the CM-4000.
The
SALVO
key can be used to execute a list of pre-built Jupiter sequences,
where a sequence is a switch of one or more sources to one or more destina-
tions.
Setting Up a Sequence
A Jupiter sequence is built using the Jupiter Sequence Set table, an
example of which is shown
Figure 36. Example of Jupiter Sequence Set table
The sequence set is given an eight-character (max) name and is of type
"3800."
In this example, sequence set "SETUP" contain two sequences: "SET UP1"
and "SETUP2." "SETUP1" will switch Cameras 1 through 3 into Monitors 1
through 3 (a total of three switches) with a single TAKE command.
"SETUP2" will reverse the order of the cameras in the monitors. Each
sequence can include up to 25 events (switches).
There is no specific limit to the number of sequences, but due to memory
restrictions a limit of 16 is recommended (e.g., "SETUP1" through
"SETUP16."
The sequence set must be assigned to the JEP-100 panel on the Jupiter MPK
Devices
table.
For additional information regarding Jupiter sequences and assigning
them to control panels, refer to the CM-4000 or CM-4400 manual.
1
Sequence Set - SETUP
Sequence
SETUP1
Input
CAM1
Levels
YYYY
2
3
4
SETUP1
CAM2
YYYY
SETUP1
CAM3
YYYY
SETUP2
CAM1
YYYY
Output
MON1
MON2
MON3
MON3
...
...
...
...
Logical
Logical
5
6
SETUP2
CAM2
YYYY
SETUP2
CAM3
YYYY
MON2
MON1
...
...
071_
8
536_02_seq-ta
b