Special entries needed to upgrade serial panels – Grass Valley JEP Series v.1.3.0 User Manual
Page 58

58
JEP Series — Installation Manual
Section 1 — JEP-100 Control Panel
list only selected inputs; such a set could be used to prevent certain panels
from selecting specific inputs.
Input Panel
- This column is not used for JEP-100 panels.
Out Set
- Output Set name.
If the entry is an actual CP Output Set, then the control panel will be able
to control all the outputs listed in that Set. Depending on the con tents of
the set, this would allow for full-matrix or multi-bus control.
Alternatively, this field can be used to enter the name of a single switcher
output to be controlled. The source of the output name is the Switcher
Output table.
Out Panel
- This column is not used for JEP-100 panels.
Level Set
- Select the CP Level Set name.
Override Set
- Not used for JEP-100 panels.
Sequence Set
- Not used for JEP-100 panels.
Special Entries Needed to Upgrade Serial Panels
In a LAN + Serial system, downloading to panels normally operated in
Serial mode will require IP settings. These settings are entered using the
web page. See