background image

JEP Series — Installation Manual

55

Configuration - Jupiter System

If the entry is an actual CP Output Set, then the control panel will be able
to control all the outputs listed in that Set. Depending on the contents of the
set, this would allow for full-matrix or multi-bus control. Use CPEXTND to
use the latest features.

Alternatively, this field can be used to enter the name of a single switcher
output to be controlled. The source of the output name is the Switcher
Output table is the same as the LAN Only mode.

Out Panel

- This column is not used for JEP-100 panels.

Level Set

- Select the CP Level Set name.

Override Set

- Not used for JEP-100 panels.

Sequence

- Same as the LAN Only mode.

Special Entries Needed to Upgrade Serial Panels

In a Serial system, downloading new software to panels normally operated
in Serial mode will require IP settings. These settings are entered using the
web page..