Serial data cables – Grass Valley JEP Series v.1.3.0 User Manual
Page 29

JEP Series — Installation Manual
29
Hardware Installation - Jupiter System
Serial Data Cables
The RS-422 cables used to connect CM-4000 or CM-4400 System Controllers
and control panels consist of a 4-conductor (plus ground) cable. Maximum
length per bus, at 115k Baud, is 610 meters (2000 ft.).
The rear panel serial data cable connectors on the CM-4000 or CM-4400 and
control panels are 9-pin D, female. The control panel connectors are
arranged for loop-through wiring. No termination is required. While these
connectors are ESbus compatible, it should be noted that the Grass Valley
serial data cables use only 5 of the 9 pins described in the ESbus specifica-
tion.
The following ready-made cables, with installed 9-pin D male connectors,
are available from Grass Valley (VDE cables include ferrite cores):
For those who wish to prepare their own cables, the pin-outs are shown in
. The cable itself should be Belden 8723 or equivalent.
Details concerning ferrite cores are given in
.
Figure 5. Serial Data Cable Wiring.
Table 3. Ready-Made Cables
1meter (3.3 ft.)
8 meters (26.2 ft.)
2 meters (6.6 ft.)
16 meters (52.5 ft.)
4 meters (13.1 ft.)
32 meters (105 ft.)
1
2
3
7
8
1
2
8
P1
DB9P
(male)
Shield (drain)
Green
Black
White
P2
DB9P
(male)
3
7
Red
Frame ground
CM-4000/4400 System
Controller
(bus controller)
Control panel or
VTR
(tributary)
Receive A (#)
Transmit A (#)
Receive B (+)
Transmit B (+)
Transmit B (+)
Transmit A (#)
Receive B (+)
Receive A (#)
Frame ground
Individually shielded, twisted pairs
Ferrite core
Ferrite core
Green
Black
White
Red
8536_11