beautypg.com

Serial data cables – Grass Valley JEP Series v.1.3.0 User Manual

Page 29

background image

JEP Series — Installation Manual

29

Hardware Installation - Jupiter System

Serial Data Cables

The RS-422 cables used to connect CM-4000 or CM-4400 System Controllers
and control panels consist of a 4-conductor (plus ground) cable. Maximum
length per bus, at 115k Baud, is 610 meters (2000 ft.).

The rear panel serial data cable connectors on the CM-4000 or CM-4400 and
control panels are 9-pin D, female. The control panel connectors are
arranged for loop-through wiring. No termination is required. While these
connectors are ESbus compatible, it should be noted that the Grass Valley
serial data cables use only 5 of the 9 pins described in the ESbus specifica-
tion.

The following ready-made cables, with installed 9-pin D male connectors,
are available from Grass Valley (VDE cables include ferrite cores):

For those who wish to prepare their own cables, the pin-outs are shown in

Figure 5

. The cable itself should be Belden 8723 or equivalent.

Details concerning ferrite cores are given in

Figure 6 on page 30

.

Figure 5. Serial Data Cable Wiring.

Table 3. Ready-Made Cables

1meter (3.3 ft.)

8 meters (26.2 ft.)

2 meters (6.6 ft.)

16 meters (52.5 ft.)

4 meters (13.1 ft.)

32 meters (105 ft.)

1

2

3

7

8

1

2

8

P1

DB9P

(male)

Shield (drain)

Green

Black

White

P2

DB9P

(male)

3

7

Red

Frame ground

CM-4000/4400 System

Controller

(bus controller)

Control panel or

VTR

(tributary)

Receive A (#)

Transmit A (#)

Receive B (+)

Transmit B (+)

Transmit B (+)

Transmit A (#)

Receive B (+)

Receive A (#)

Frame ground

Individually shielded, twisted pairs

Ferrite core

Ferrite core

Green

Black

White

Red

8536_11