Serial system – Grass Valley JEP Series v.1.3.0 User Manual
Page 33

JEP Series — Installation Manual
33
Internet Protocol Configuration
Serial System
shows an example of a system addressing where the JEP-100s will
be operated in Serial mode (the LAN connections are for software
upgrade). Because there are more than 16 panels, the 17th panel must be
connected to a second CM port. This results in two panels with an ID of
“01.”
This arrangement assumes that the LAN connections will be made to one
panel at a time only for the purpose of software upgrade. In this case, it isn't
necessary to have a different IP address for each panel; however, to prevent
confusion if more than one panel is connected it is recommended that
unique IP addresses are assigned.
Figure 8. Serial System Addressing (example).
CM-4400 or
CM-4000 System Controller
Serial
Ports
100baseT Jupi-
ter LAN
IP switch
Serial
buses
Panel IP
“192.168.253.102”
Panel ID
“02”
Panel IP
“192.168.253.101”
Panel ID
“01”
Panel IP
“192.168.253.116”
Panel ID
“16”
Panel IP
“192.168.253.117”
Panel ID
“01”
IP
“192.168.253.10”
Jupiter
File Server
“192.168.253.1”
8536_14