Grass Valley FT Server User Manual

Page 62

background image

Action

Possible Cause

Meaning

Name

Green: duplexing

System can work even
if a module is pulled
out.

Green blinking:
Simplexing

System can not work if
a module is pulled out.

Off: Some offline parts
exist.

System can work even
if a module is pulled
out.

Showing condition
whether a module can
be unmounted or not.

SAFE TO PULL

Replace CPU/IO
module.

Processor failure

CPU/IO module failure

DIMM failure

Amber LED illuminates
when a failure occurs in
CPU of CPU/IO
module.

CPU (CPU part error
LED)

Replace CPU/IO
module.

CPU/IO module failure

PCI Board failure

Amber LED illuminates
when a failure occurs in
I/O of CPU/IO module.

I/O (I/O part error
LED)

Replace CPU/IO
module.

CPU/IO module failure

Power Supply Unit
failure

Amber LED illuminates
when electric voltage
failure occurs in
CPU/IO module.

VLT (Power error
LED)

Replace CPU/IO
Module.

Four LEDs indicate
DIMM Slot number.

Target DIMM failure

CPU/IO Module failure

Processor failure

Amber LED illuminates
when a failure occurs
on the memory of
CPU/IO module.

MEM NUMBER
(Memory slot error
LED)

Replace CPU/IO
module.

The LED turns on if DC
power is not provided
in spite of power on
request.

Processor failure

CPU/IO module failure

Amber LED illuminates
when failure occurs on
the power supply unit
of CPU/IO module.

PSU (Power Supply
Unit error LED)

62

FT Server Instruction Manual

20131220

Servicing the FT Server