Grass Valley FT Server User Manual
Page 32
![background image](https://www.manualsdir.com/files/813485/content/doc032.png)
The POST running LCD format is shown in the table below.
F
E
D
C
B
A
9
8
7
6
5
4
3
2
1
0
Z
Z
Z
Z
S
O
I
B
X
X
X
X
0
1
The POST running LCD format detail is shown in the table below.
Description
Display
Normal: Currently executing POST code
XXXX
BIOS Build Number
ZZZZ
The message displays the state of duplication on the upper row of LCD by software driver after the
OS boots.
The Boot message for the Virtual LCD is shown in the table below.
Action
Comments
Representation
Row
LCD Message
The module
displayed LCD
is broken.
Change the
broken CPU/IO
module.
If CPU part is
broken, LCD is
displayed on the
broken CPU/IO
modules.
DC ON
Upper
CPU broken
The module
displayed LCD
is broken.
Change the
broken CPU/IO
module or PCI
card.
If IO part is
broken, LCD is
displayed on the
broken CPU/IO
modules.
DC ON
Upper
I/O broken
System duplex
completed.
When the
system is under
duplex mode,
the message is
displayed on
both CPU/IO
modules.
DC ON
Upper
System Duplex
The system is
working under
simplex mode.
When system is
not under
duplex mode,
the message is
displayed on the
CPU/IO module
working
normally.
DC ON
Upper
System Simplex
32
FT Server Instruction Manual
20131220