4. Without a physical LTC connection, timecode can still be polled via RS-422. Check

the option to enable RS-422 timecode mode in the Add VTR window if you want
to poll the timecode.

Records with RS-422 timecode mode have a frame accuracy recording window
of +/- 10 frames. Due to this, in and out handle settings are provided within the
setup.

Once configured, timecode is no longer a required input and records on VTR
Ingest will be triggered with timecode detection via RS-422.

5. You can set In and Out Handles for recordings with VTR using the RS-422 timecode

mode. Both handles are set to 10 frames by default.

6. If you are using an XDCAM VTR, you can select the checkbox to enable auto scan

for the XDCAM VTR.

The XDCAM VTR does not adhere to typical RS-422 shuttle commands. By
enabling the auto scan feature for XDCAM VTR, previous and next commands
will be used instead of the usual shuttle forward and back.

7. You can also change the shuttle speed for the auto scan feature.

The default is set to 32, but you can change to any value depending on the type
of VTR that you use. When XDCAM mode is selected, the field to set the shuttle
speed of auto scan will be disabled.

8. Click

OK

to add the VTR.

14 April 2010

Aurora Ingest System Guide

99