Configuration Summary Table
Reset EDH/CRC errors on Primary,
Secondary, and Alternate signals
-
Reset
HD/SD Criteria
EDH/CRC Errors
EDH/CRC Detected Errors
RESET buttons
N/A
Set PID for Stream Criteria, Primary
Stream, Streams 1-4
Stream 1 - PID 0
Stream 2 - PID 1
Stream 3 - PID 2
Stream 4 - PID 3
0 to 8191
DVB/ASI Criteria
Stream Criteria, Primary Stream
Stream 1-4
Enter value into PID boxes 1-4
N/A
Stream Criteria, Secondary Stream, for
streams 1-4
Follows Primary Stream
DVB/ASI Criteria
Stream Criteria, Secondary Stream
Stream 1-4
Follows Primary Stream
Set Stream Criteria, Alternate Stream,
for streams 1-4
Stream 1 - PID 0
Stream 2 - PID 1
Stream 3 - PID 2
Stream 4 - PID 3
0 to 8191
DVB/ASI Criteria
Stream Criteria, Alternate Stream
Stream 1-4
Enter value into PID boxes 1-4
Enable Presence reporting for
Primary Streams 1-4
Disabled
Enable or Disable
DVB/ASI Criteria
Stream Criteria, Primary Stream
Stream 1-4
Criteria/Presence
Presence Enable checkboxes 1-4
PSSt1PreEn
PSSt2PreEn
PSSt3PreEn
PSSt4PreEn
Enable Presence reporting for
Secondary Streams 1-4
Follows Primary Stream
DVB/ASI Criteria
Stream Criteria, Secondary Stream
Stream 1-4
Criteria/Presence
Follows Primary Stream
Enable Presence reporting for
Alternate Streams 1-4
Disabled
Enable or Disable
DVB/ASI Criteria
Stream Criteria, Alternate Stream
Stream 1-4
Criteria/Presence
Presence Enable checkboxes 1-4
AlSt1PreEn
AlSt2PreEn
AlSt3PreEn
AlSt4PreEn
Enable Continuity Error reporting for
Primary Streams 1-4
Disabled
Enable or Disable
DVB/ASI Criteria
Stream Criteria, Primary Stream
Stream 1-4
Criteria/Continuity Errors
Continuity Errors Enable checkboxes 1-4
PSSt1CCErEn
PSSt2CCErEn
PSSt3CCErEn
PSSt4CCErEn
Enable Continuity Error reporting for
Secondary Streams 1-4
Follows Primary Stream
DVB/ASI Criteria
Stream Criteria, Secondary Stream
Stream 1-4
Criteria/Continuity Errors
Follows Primary Stream
Enable Continuity Error reporting for
Alternate Streams 1-4
Disabled
Enable or Disable
DVB/ASI Criteria
Stream Criteria, Alternate Stream
Stream 1-4
Criteria/Continuity Errors
Continuity Errors Enable checkboxes 1-4
ASt1CCErEn
ASt2CCErEn
ASt3CCErEn
ASt4CCErEn
Force Primary, Secondary, or Alternate
with web page manual control.
(Selecting Force Primary, Force Sec-
ondary or Force Alternate sets Switch-
back Strategy mode to
Manual).
If Switchback Strategy is set to
Maintain Primary or Maintain Stability,
this control will be set to
Autonomous.
Autonomous
Force Primary,
Force Secondary,
Force Alternate,
or Autonomous
Output Control/
Program Output Selection
Input
Force Primary button
PgrOutSel
Output Control/
Program Output Selection
Input
Force Secondary button
Output Control/
Program Output Selection
Input
Force Alternate button
Table 12. Summary of 8972PX Configuration Functions
Function
Type
Default
Range/Choices
Resolution