Grass Valley 8972PX User Manual
Page 47

8972PX — Instruction Manual
47
Configuration
Web Page Headers
Each configuration web page has a Status and Identification Header as
shown in
. The information provided tells the current status of the
following:
•
Model
and
Description
are read-only generated by the module.
•
Frame Location
is defined on the 8900 Series GeckoFlex Frame Configura-
tion web page.
•
Slot
number reports the module’s location in the frame.
•
Primary Input
reports the presence of a signal on the Primary Input BNC
J9, the status of the input (
Good
,
Not Good
, or
Not Monitored
), and the line
standard.
•
Secondary Input
reports the presence of a signal on the Secondary Input
BNC J10, the status of the input (
Good
,
Not Good
, or
Not Monitored
), and the
line standard.
•
Alternate Input
reports the presence of a signal on the Alternate Input
BNC J11, the status of the input (
Good
,
Not Good
, or
Not Monitored
), and the
line standard.
•
Program Output
reports the current input present at the Program Output
BNCs J5 and J7 (
Primary
,
Secondary
, or
Alternate
).
•
Backup Candidate
reports the next input that will become active upon
Program failure. The Backup Candidate is always different than the
Program.
Figure 18. Web Page Header Information
Web pages with configuration parameters each have a
Defaults
button at the
bottom of the page to allow resetting of default parameters for only that
page. Default values are summarized for all module parameters in
.