beautypg.com

Grass Valley 8972PX User Manual

Page 17

background image

8972PX — Instruction Manual

17

Configuration Summary

HD/SD Criteria

When the input signal is HD or SD SDI video, the signal health status is
based on the following criteria as analyzed by the module. These criteria
are always enabled and the module will determine module health by
checking each item below.

The signal is considered

Good

when:

Carrier Detect – a valid carrier is detected on the input,

Serial Lock – the serial receiver is locked to a SMPTE compliant data
stream,

Valid Format – the input signal matches the selected input selection,

SMPTE Presence – no instability has been detected for a valid format,
and

No SMPTE TRS Errors – no TRS (Timing Reference Signal) errors have
been detected.

If any one of these criteria are incorrect for the input type selected, the
signal will be reported as

Not Good

. When this happens, the following cases

occur depending on the Switching Strategy Switch Mode selected in con-
figuration:

If the Switchback Strategy Switch Mode is set for

Maintain Primary

, the

module will switch the Program Output immediately to the Backup
Candidate. It will return the Primary input to the Program Output as
soon as the Primary input becomes good again in the time set with the
Switchback Delay control on the Output Control web page or with the
Newton Control Panel.

If the Switchback Strategy Switch Mode is set for

Maintain Stability

, when

the Primary input is detected as

Not Good

, the module will switch the

Program Output immediately to the next valid Backup Candidate and
remain there until the user decides to manually override the selection
to return the Primary input to the Program output or the Backup Can-
didate fails.

An optional criteria category to check for EDH/CRC errors can be enabled
by checking the EDH/CRC

Enable

checkbox.

The error detection process is done independently on each input channel
for both SMPTE 292M and SMPTE 259M. The error threshold (number and
total of fields allowed before the signal is considered not good) can be
selected with the controls provided.