Using additional snmp commands, Using additional snmp – Grass Valley 8972PX User Manual
Page 80

80
8972PX — Instruction Manual
Appendix — SNMP Features
Using Additional SNMP Commands
To select the program input, use this parameter
(mcmFssInputSelect, OID 1.3.6.1.4.1.4947.2.3.2.1.2.4.1.8.slot#)
•
input-primary (1)
•
input-secondary (2)
•
input-alternate (3)
To select the mode of operation, use this parameter:
(mcmFssSwitchbackStrategy, OID 1.3.6.1.4.1.4947.2.3.2.1.2.4.1.73.slot#)
•
maintain-stability (1)
•
maintain-primary (2)
•
manual (3)
Note the following about using these commands:
•
Setting the Program Input via SNMP (set mcmFssInputSelect) is equiv-
alent to forcing the input with NetConfig.
•
Reading the Program Input via SNMP (get mcmFssInputSelect) is just
receiving information about the current input.
•
Setting the Switch Mode via SNMP (set mcmFssSwitchBack-Strategy)
is equivalent to forcing the Switch Mode with NetConfig.
•
Reading the Switch Mode via SNMP (get mcmFssSwitchBack-Strategy)
is just receiving information about the current Switch Mode.
Note
These two parameters behave the same with SNMP as for NetConfig or using
the Newton Control Panel. In particular, if a specific input is forced, the
module mode of operation becomes Manual.
For help in locating these MIB commands, the Input Select command is
highlighted in the tree in
and the Switchback Strategy
is highlighted the tree in
.