H3C Technologies H3C SecBlade LB Cards User Manual
Page 133
125
Step Command
Remarks
4.
Configure
threshold
monitoring.
•
Enable sending traps to the NMS when specified conditions
are met:
reaction trap { probe-failure consecutive-probe-failures |
test-complete | test-failure cumulate-probe-failures }
•
Configure a reaction entry for monitoring the duration of an
NQA operation (not supported in UDP jitter and voice
operations):
reaction item-number checked-element probe-duration
threshold-type { accumulate accumulate-occurrences |
average | consecutive consecutive-occurrences }
threshold-value upper-threshold lower-threshold [ action-type
{ none | trap-only } ]
•
Configure a reaction entry for monitoring failure times (not
supported in UDP jitter and voice operations):
reaction item-number checked-element probe-fail
threshold-type { accumulate accumulate-occurrences |
consecutive consecutive-occurrences } [ action-type { none |
trap-only } ]
•
Configure a reaction entry for monitoring the round-trip time
(only supported in UDP jitter and voice operations):
reaction item-number checked-element rtt threshold-type
{ accumulate accumulate-occurrences | average }
threshold-value upper-threshold lower-threshold [ action-type
{ none | trap-only } ]
•
Configure a reaction entry for monitoring packet loss (only
supported in UDP jitter and voice operations):
reaction item-number checked-element packet-loss
threshold-type accumulate accumulate-occurrences
[ action-type { none | trap-only } ]
•
Configure a reaction entry for monitoring one-way jitter (only
supported in UDP jitter and voice operations):
reaction item-number checked-element { jitter-ds | jitter-sd }
threshold-type { accumulate accumulate-occurrences |
average } threshold-value upper-threshold lower-threshold
[ action-type { none | trap-only } ]
•
Configure a reaction entry for monitoring the one-way delay
(only supported in UDP jitter and voice operations):
reaction item-number checked-element { owd-ds | owd-sd }
threshold-value upper-threshold lower-threshold
•
Configure a reaction entry for monitoring the ICPIF value
(only supported in the voice operation):
reaction item-number checked-element icpif threshold-value
upper-threshold lower-threshold [ action-type { none |
trap-only } ]
•
Configure a reaction entry for monitoring the MOS value
(only supported in the voice operation):
reaction item-number checked-element mos threshold-value
upper-threshold lower-threshold [ action-type { none |
trap-only } ]
Configure the
trap sending
method as
needed.
No traps are
sent to the NMS
by default.
The reaction
trap command
in voice
operation view
only supports
the
test-complete
keyword.