To configure optional parameters for an NQA operation:

Step Command

Remarks

1.

Enter system view.

system-view

N/A

2.

Create an NQA
operation and enter

NQA operation view.

nqa entry admin-name
operation-tag

By default, no NQA operation is created.

3.

Specify an NQA

operation type and
enter its view.

type { dhcp | dlsw | dns | ftp |
http | icmp-echo | snmp | tcp |

udp-echo | udp-jitter | voice }

N/A

4.

Configure a
description.

description text

Optional.
By default, no description is configured.

5.

Specify the interval at
which the NQA

operation repeats.

frequency interval

Optional.
By default, the interval is 0 milliseconds.
Only one operation is performed.
If the operation is not completed when the

interval expires, the next operation does
not start.

6.

Specify the probe

times.

probe count times

Optional.
By default, an NQA operation performs
one probe.
The voice operation can perform only one
probe, and does not support this

command.

7.

Specify the probe
timeout time.

probe timeout timeout

Optional.
By default, the timeout time is 3000
milliseconds.
This setting is not available for the UDP

jitter or voice operation.

8.

Specify the TTL for
probe packets.

ttl value

Optional.
20 by default.
This setting is not available for the DHCP

operation.

9.

Specify the ToS value
in the IP packet header

of probe packets.

tos value

Optional.
0 by default.
This setting is not available for the DHCP

operation.

10.

Enable the routing
table bypass function. route-option bypass-route

Optional.
Disabled by default.
This setting is not available for the DHCP

operation.