Configuring spanning tree timers

The following timers are used for spanning tree calculation:

Forward delay

It is the delay time for port state transition. To prevent temporary loops on a network, the spanning tree

sets an intermediate port state, the learning state, before it transitions from the discarding state to the

forwarding state, and requires that the port transitions its state after a forward delay timer to ensure that
the state transition of the local port keeps synchronized with the peer.

Hello time

The device detects whether a link failure has occurred with the hello time interval. The spanning tree

sends out a configuration BPDU every hello time interval. If the device receives no configuration BPDUs

within the hello time interval, it recalculates the spanning tree.

Max age

In the CIST of an MSTP network, the device determines whether a configuration BPDU received by a port
has expires based on the max age timer. If yes, a new spanning tree calculation process starts. The max

age timer is ineffective for MSTIs.
To prevent network instability, make sure that the timer settings meet the following formulas:

2 × (forward delay – 1 second) ú max age

Max age ú 2 × (hello time + 1 second)

H3C does not recommend you to manually set the spanning tree timers. Instead, you can specify the

network diameter and let spanning tree protocols automatically calculate the timers based on the
network diameter. If the network diameter uses the default value, the timers also use their default values.
Configure the timers on the root bridge only, and the timer settings on the root bridge apply to all the

devices on the entire switched network.
Follow these steps to configure the spanning tree timers:

To do...

Use the command...

Remarks

Enter system view

system-view

Configure the forward delay timer stp timer forward-delay time

Optional
1500 centiseconds by default.

Configure the hello timer

stp timer hello time

Optional
200 centiseconds by default.

Configure the max age timer

stp timer max-age time

Optional
2000 centiseconds by default.