Configuring the GARP timers

Follow these steps to configure the GARP timers:

To do…

Use the command…

Remarks

Enter system view

system-view

––

Configure the GARP LeaveAll timer

garp timer leaveall timer-value

Optional
1000 centiseconds by default.
The LeaveAll timer applies to all

ports.

Enter Ethernet
interface
view, Layer 2

aggregate

interface
view, or

port-group

view

Enter Ethernet or
Layer 2 aggregate

interface view

interface interface-type
interface-number

Required
Use either command.

Enter port-group
view

port-group manual
port-group-name

Configure the Hold timer

garp timer hold timer-value

Optional
10 centiseconds by default.

Configure the Join timer

garp timer join timer-value

Optional
20 centiseconds by default.

Configure the Leave timer

garp timer leave timer-value

Optional
60 centiseconds by default.

As shown in

Table 19

, the value ranges for GARP timers are dependent on one another:

If you want to set a value beyond the value range for a timer, you may change the value range by
tuning the value of another related timer.

If you want to restore the default settings of the timers, restore the Hold timer first, and then the Join,
Leave, and LeaveAll timers.

Table 19 Dependencies of the GARP timers

Timer Lower

limit

Upper limit

Hold

10 centiseconds

No greater than half of the Join timer

Join

No less than twice the Hold timer

Less than half of the Leave timer

Leave

Greater than twice the Join timer

Less than the LeaveAll timer

LeaveAll

Greater than the Leave timer

32765 centiseconds