Westermo MRI-128-F4G-PSE24 User Manual
Page 68

64
Temperature 2 : 41 degree
Temperature 3 : 47 degree
Power information :
Budget :
DC Power 1 : 400 Watts (In Use)
DC Power 2 : 400 Watts
AC Power : 300 Watts (In Use)
Total : 1100 Watts
700 Watts in Use
Warning water level : N/A
Utilization : 0 %
Event : Normal
Syntax
show poe interface IFNAME
Parameters
IFNAME : interface name
Command Mode
Enable mode
Description
Display the PoE status of interface.
Examples
Switch> enable
Switch# show poe interface fa1
Interface fastethernet1 (POE Port 1)
Control Mode : User (Disable)
Powering Mode : 802.3af
Operation Status : Off
Detection Status : Valid
Classification : N/A
Priority : Highest
Output Power : 0.0 Watts, Voltage : 0.0 V, Current : 0
mA
Power Budget :
Budget : 32.0 Watts, effective 0 Watts
Warning water level : N/A
Utilization : 0 %
Event : Normal
Syntax
show poe pd_detect
Parameters
--
Command Mode
Enable mode
Description
Display the status of pd status detection.
Examples
Switch# show poe pd-detect
PD Status Detection