Command lines of the warning configuration – Westermo MRI-128-F4G-PSE24 User Manual
Page 149

145
Command Lines of the Warning configuration
Feature
Command Line
Relay Output
Relay Output
Switch(config)# relay 1
dry dry output
ping ping failure
port port link failure
power power failure
ring super ring failure
Dry Output
Switch(config)# relay 1 dry
<0-4294967295> turn on period in second
Switch(config)# relay 1 dry 5
<0-4294967295> turn off period in second
Switch(config)# relay 1 dry 5 5
Ping Failure
Switch(config)# relay 1 ping 192.168.2.200
reset reset a device
Switch(config)# relay 1 ping 192.168.2.200 reset
<1-65535> reset time
Switch(config)# relay 1 ping 192.168.2.200 reset
60
<0-65535> hold time to retry
Switch(config)# relay 1 ping 192.168.2.200 reset
60 60
Port Link Failure Switch(config)# relay 1 port
PORTLIST port list
Switch(config)# relay 1 port fa1-5
Power Failure
Switch(config)# relay 1 power
<1-3> power id (1: AC, 2: DC1, 3:DC2)
any Anyone power failure asserts relay
Switch(config)# relay 1 power 1
Switch(config)# relay 1 power 2
Super Ring Failure Switch(config)# relay 1 ring
Disable Relay
R. Switch(config)# no rel1 relay id
Switch(config)# no relay 1 (Relay_ID: 1 or 2)
Display
Switch# show relay 1