Warning – Westermo MRI-128-F4G-PSE24 User Manual
Page 142

138
4.12 Warning
The switch provides several types of Warning features for you to remote monitor
the status of end devices or the change of your network. The features include
Fault Relay, System Log and SMTP E-mail Alert.
Following commands are included in this chapter:
4.12.1 Fault Relay
4.12.2 Event Selection
4.12.3 Syslog Configuration
4.12.4 SMTP Configuration
4.12.5 CLI Commands
4.12.1 Fault Relay
The switch provides one digital output, also known as Relay Output. The relay
contacts are energized (open) for normal operation and will close under fault
conditions. Fault conditions include Power Failure, Ethernet port Link Failure,
Ping Failure and Super Ring Topology Change. You can configure these settings in
this Fault Relay Setting and each Relay can be assigned 1 fault condition.
Relay 1: Click on checkbox of the Relay 1, then select the Event Type and its
parameters.
Event Type: Dry Output, Power Failure, Link Failure, Ping Failure and Super Ring
Failure. Each event type has its own parameters and should also be configured.
Currently, each Relay has one event type.
Event Type: Dry Output
On Period (Sec): Type the period time to turn on Relay Output. Available range of