Performance Monitoring

5-10

Verilink QUAD/IMUX User Manual

Table 5-4

IMUX Performance/Status Menu

Field Name

Description

Data Port Type

Displays the type of data port. Types are: HSSI, V.35, EIA 530, EIA 530A, and RS-449.

DTR

Displays the HSSI status of the Data Terminal Ready parameter. Only appears if the

DTE interface is HSSI.

Loop type A

Reports the status of Interchange circuit 143 (Loop A). Only appears if the DTE

interface is HSSI. According to the HSSI specification, and absence of A and B means

no loopback is requested. The presence of A and the absence of B means a Local Line

Loopback has been requested (Loop C).

The absence of A and the presence of B means a Remote Line Loopback has been

requested (Loop B). The presence of A and B means a Local Digital Loopback has been

requested (Loop A).

Verilink refers to a Loop A as an Equipment Loopback (IMUX ELB), and Loop B as a

Local Loopback in the QUAD 2164 module applied to all active lines used by the IMUX

2160 modules.

Loop type B

Reports the status of Interchange circuit 144 (Loop B). Only appears if the DTE

interface is HSSI.

AIS Pattern

Displays the status of the Alarm Indication Signal (AIS) pattern. Valid options are

Disabled, ALL ONES, ALL ZEROS.

Loopback

Shows which loopback (if any) is active. Valid options are NONE, ELB, and PLB.

Lines Equipped

Shows the status of each of the lines configured for use by the selected IMUX 2160

module.

Lines Active

Shows which lines are in use by the selected IMUX 2160 module. The IMUX 2160

module will use a line that has been “equipped” only if Frame Sync and Clear To Send

signals are active.

Frame Status

Shows that the selected IMUX 2160 module has recognized and synchronized with

the IMUX frame structure on the incoming (RX) signal on these lines.

CTS Status

Shows that the selected IMUX 2160 module has received via IMUX Frame signalling

bits, confirmation of frame detection and synchronization by the far-end IMUX 2160

module on these lines.

CRC Status

Shows that a Cyclic Redundancy Check error was detected in one or more of a group

of five IMUX frames on these lines.

Far CRC Status

Shows that a Cyclic Redundancy Check error was detected by the far-end IMUX 2160

module in one or more of a group of five IMUX frames on these lines.

Main Menu

Use this option to return to the Main Menu.