E1 Configuration Menus
Verilink QUAD/IMUX User Manual
3-11
Slip Address
Do not configure SLIP on the QUAD 2164. There is no physical interface on the
QUAD 2164 which supports SLIP. Errors made while configuring SLIP may
lockup the module, requiring factory repair.
Slip Sub-net Mask
Do not configure SLIP on the QUAD 2164. There is no physical interface on the
QUAD 2164 which supports SLIP. Errors made while configuring SLIP may
lockup the module, requiring factory repair.
Trap Addresses
This field displays the SNMP trap IP addresses for each port. To change this
address, type “N” (network parameters), then “Pn” (trap addresses), where n is
the number of the QUAD port. See
Gateway Address
This field displays the IP address of the node’s gateway. To change this address,
type “N” (network parameters), then “G” (gateway ip address). See
.
Read Community
String
This field displays the SNMP community read string state. To change this state,
type “N” (network parameters), then R (SNMP read community string). Sample
strings include NETMGT and PUBLIC. See
Write Community
String
This field displays the SNMP community write string state. To change this state,
type “N” (network parameters), then “W” (SNMP write community string). Sample
strings include NETMGT and PUBLIC. See
System Uptime
This field displays the amount of time (in hours, minutes, and seconds) that the
node has been operating. It resets to zero every time the node is rebooted.
N
Network Parameters—Use this field to change any of the network parameters
displayed on the Administration Menu.
M
Modem Parameters—Not available with this product.
R
Reset Card—Returns the QUAD 2164 module to its factory default values. Press
“
Y
”
to confirm this action.
P
Change Password—Sets privileged and unprivileged passwords. At the Password
Menu, type “P” to set privileged passwords. Type “U” to set unprivileged
passwords. Privileged users have network administrator permissions and can
change all parameters. Unprivileged users have run time access to QUAD 2164
module capabilities, but cannot make changes to parameters.
Q
Query Firmware—Verifies the status of the firmware and memory in the active
partition (A or B). When you type “Q’, the screen reports the version level and
status of the partition firmware and RAM.
Y
Switch Over Once—Switches the active firmware partition (used typically to test
new firmware). At the prompt, select the partition (A or B) to switch to
temporarily. When you reboot the card, the original partition will be used.
O
Switch Over Permanent—Permanently switches the active firmware partition. At
the prompt, select the partition (A or B) to switch to permanently. When you
reboot the card, this new partition is used as the boot partition.
W
write File to Flash—Updates the flash image in the nonactive partition. Requires
overwrite confirmation of the nonactive partition.
B
Change ACP Bus—Changes the ACP communications bus. Reset the card after
the change is made.
X
Main Menu—Return to the main menu.