This section discusses the T1 IMUX 2160 module configuration.

T1 IMUX

Configuration

Menu

To display the Configuration Menu, select an IMUX 2160 module
from the Main Menu and type “C” for configuration. The T1 IMUX
Configuration Menu appears (

Figure 4-8

).

Figure 4-8 T1 IMUX Configuration Screen

NOTE: Careful consideration must be given to the selection for DTE

handshake. If MANUAL is selected every control lead is

immediately forced off. The required control leads must then

be forced on. In MANUAL DTE Handshake mode DSR must be

forced on or no data will be transmitted. In AUTOMATIC

mode the DTE must assert DTR or DSR will not be returned

and no data will be transmitted.

Table 4-7

T1 IMUX Configuration Menu

Command

Description

L

Line Type—Selects or displays the line configuration. Valid choices are T1 or E1.

C

Channel Rate—Selects or displays the data rate per DS0. Valid choices are 64K

and 56K. If using an AMI T1 facility, 56K is required. For a B8ZS T1 or any E1, 64K

can be used.

-- IMUX 2160 CONFIGURATION MENU --

-- IMUX 2160 CONFIGURATION MENU --

-- IMUX 2160 CONFIGURATION MENU --

-- IMUX 2160 CONFIGURATION MENU --

L) Line Type : T1 1) DSR NO

L) Line Type : T1 1) DSR NO

L) Line Type : T1 1) DSR NO

L) Line Type : T1 1) DSR NO
C) Channel Rate: 64K 2) CTS NO

C) Channel Rate: 64K 2) CTS NO

C) Channel Rate: 64K 2) CTS NO

C) Channel Rate: 64K 2) CTS NO
R) Rx Clk Phase: INVERT 3) DCD YES

R) Rx Clk Phase: INVERT 3) DCD YES

R) Rx Clk Phase: INVERT 3) DCD YES

R) Rx Clk Phase: INVERT 3) DCD YES
T) Tx Clk Phase: INVERT 4) RI YES

T) Tx Clk Phase: INVERT 4) RI YES

T) Tx Clk Phase: INVERT 4) RI YES

T) Tx Clk Phase: INVERT 4) RI YES
F) Ref Clk Phase: NORMAL 5) TM NO

F) Ref Clk Phase: NORMAL 5) TM NO

F) Ref Clk Phase: NORMAL 5) TM NO

F) Ref Clk Phase: NORMAL 5) TM NO
H) DTE Handshake: AUTOMATIC

H) DTE Handshake: AUTOMATIC

H) DTE Handshake: AUTOMATIC

H) DTE Handshake: AUTOMATIC
DTE Type: V.35

DTE Type: V.35

DTE Type: V.35

DTE Type: V.35
Q1) Quad Card 1: 1 2 3 4

Q1) Quad Card 1: 1 2 3 4

Q1) Quad Card 1: 1 2 3 4

Q1) Quad Card 1: 1 2 3 4
Q2) Quad Card 2:

Q2) Quad Card 2:

Q2) Quad Card 2:

Q2) Quad Card 2:

1 2 3 4 5 6 7 8

1 2 3 4 5 6 7 8

1 2 3 4 5 6 7 8

1 2 3 4 5 6 7 8
Lines Equipped: X X X X

Lines Equipped: X X X X

Lines Equipped: X X X X

Lines Equipped: X X X X
Lines Active: X X X X

Lines Active: X X X X

Lines Active: X X X X

Lines Active: X X X X
Frame Status: X X X X

Frame Status: X X X X

Frame Status: X X X X

Frame Status: X X X X
CTS Status: X X X X

CTS Status: X X X X

CTS Status: X X X X

CTS Status: X X X X
CRC Status:

CRC Status:

CRC Status:

CRC Status:
Far CRC Status:

Far CRC Status:

Far CRC Status:

Far CRC Status:

X) main menu

X) main menu

X) main menu

X) main menu

[1,2] IMUX 2160 >

[1,2] IMUX 2160 >

[1,2] IMUX 2160 >

[1,2] IMUX 2160 >