Verilink DIDCSU 2912 (880-502646-001) Product Manual User Manual
Page 98

DIDCSU E1 Version
4-26
Verilink DIDCSU 2912 User Manual
Table 4-14 Net Port Alarm Threshold Configuration Menu Parameters
Command
Description
Options
Pn
Dn
Alarm Reporting: Enabling alarm reporting transmits alarm messages to
both the ASCII interface and Node Manager. If this option is set to No,
alarms will not be reported. The LEDs turn red in an alarm condition. Set
this option to No when configuring the node. Set to Yes during normal
operation.
Yes or No
(Y/N)
Fn
Loss-of-Frame (LOF) Threshold/LOF Interval: Use this option to indicate
an interval that is greater than the threshold.
Threshold:
1—86400
0 to disable
Interval:
3—86400
seconds
Ln
Loss-of-Signal (LOS) Threshold/LOS Interval: Use this option to indicate an
interval that is greater than the threshold.
If LOS occurs, troubleshoot this situation first and ignore all other
alarms. (There will be other alarms.) This is the most severe alarm.
Threshold:
1—86400
0 to disable
Interval:
3—86400
seconds
Rn
Remote Alarm Indication (RAI) Threshold/RAI Interval: Use this option to
indicate an interval that is greater than the threshold.
Threshold:
1—86400
0 to disable
Interval:
1—86400
seconds
An
Alarm Indication Signal (AIS) Threshold/AIS Interval: Use this option to
indicate an interval that is greater than the threshold.
Threshold:
1—86400
0 to disable
Interval:
1—86400
seconds
Bn
Bipolar Violation (BPV) Threshold/BPV Interval: Use this option to indicate
an interval that is greater than the threshold.
Threshold:
1—86400
0 to disable
Interval:
1—86400
seconds
En
Errored Seconds (ES) 15 min. Threshold/ES 24 hr. Threshold: An ES alarm
indicates a second with one or more errors.
15 minute
Threshold:
1—900
0 to disable
24 hour
Threshold:
1—86400
0 to disable