beautypg.com

Verilink DIDCSU 2912 (880-502646-001) Product Manual User Manual

Page 52

background image

DIDCSU T1 Version

3-12

Verilink DIDCSU 2912 User Manual

Table 3-6

Configuration Menu (Timing Options) Parameters

Command

Description

Options

R

Receive Clock from Shelf: Use this option to indicate the DIDCSU

receives its timing signal from another card in the shelf, or from an on-

board timing source.

Note: Changing this option toggles between the shelf timing and

card timing menus.

Yes or No

(Y/N)

PS

Primary Synchronization: Choose one of the following as your primary

source for clock synchronization.

• Net 1: T1 Port 1

• Net 2: T1 Port 2

• External: External clock

• Internal: Internal clock

• Data 1: Data Port 1 TT input signal

• Data 2: Data Port 2 TT input signal

1) NET 1

2) NET 2

3) EXTERNAL

4) INTERNAL

5) DATA 1

6) DATA 2

SS

Secondary Synchronization: Use this option to specify an alternate

source of timing for synchronization. If the primary source is

unavailable, this source is used.

• Net 1: T1 Port 1

• Net 2: T1 Port 2

• External: External clock

• Internal: Internal clock

• Data 1: Data Port 1 TT input signal

• Data 2: Data Port 2 TT input signal

1) NET 1

2) NET 2

3) EXTERNAL

4) INTERNAL

5) DATA 1

6) DATA 2

TS

Tertiary Synchronization: Use this option to specify an alternate source

of timing for synchronization. If the primary and secondary source are

unavailable, this source is used.

• Net 1: T1 Port 1

• Net 2: T1 Port 2

• External: External clock

• Internal: Internal clock

• Data 1: Data Port 1 TT input signal

• Data 2: Data Port 2 TT input signal

1) NET 1

2) NET 2

3) EXTERNAL

4) INTERNAL

5) DATA 1

6) DATA 2

PA

Primary Auto Restore: Select Yes to resynchronize to the clock source

automatically if a previously failed clock source becomes available

again. Otherwise, choose No. Setting up auto restore returns timing to a

higher priority source after a failure clears.

Yes or No