Figure 2-5 – Verilink DIDCSU 2912 (880-502646-001) Product Manual User Manual
Page 23

DIDCSU 2912 Quick Set-Up
Verilink DIDCSU 2912 User Manual
2
-
5
Figure 2-5 T1 Port Configuration Menu
Place Ports In
Service
13. In the T1 Port Configuration Menu, type the letter “
I
” and the
number “1”, press E
NTER
, then type “Y”,and press E
NTER
, to
place Net Port 1 In Service. Type “
I
2”, press E
NTER
, then
respond by pressing “Y”, E
NTER
, to place Net Port 2 In Service.
NOTE: For the remainder of this section you will not be instructed
each time you should press the E
NTER
key. In general, E
NTER
is
used after each command or text entry.
Select ESF Framing
14. Type “F1”, and “2” for ESF framing for Net Port 1. Type “F2”
and “2” for ESF framing for Net Port 2.
Select B8ZS Line
Coding
15. Type “L1”, then “2” to select B8ZS as the line coding for Net
Port 1. Type “L2”, then “2” to select B8ZS as the line coding for
Net Port 2.
Set Line Build Out
to 0db
16. Type “B1”, then “1” to select 0db as the line build out for Net
Port 1. Type “B2”, then “1” to select 0db as the line build out
for Net Port 2.
Set Density
Enforcement to
None
17. Type “ND1”, then “1” to select NONE as the network density
for Net Port 1. Type “ND2”, then “1” to select NONE as the
network density for Net Port 2.
-- DIDCSU 2912 T1 PORT CONFIGURATION MENU --
-- DIDCSU 2912 T1 PORT CONFIGURATION MENU --
-- DIDCSU 2912 T1 PORT CONFIGURATION MENU --
-- DIDCSU 2912 T1 PORT CONFIGURATION MENU --
PORT 1 PORT 2
PORT 1 PORT 2
PORT 1 PORT 2
PORT 1 PORT 2
In) In Service YES YES
In) In Service YES YES
In) In Service YES YES
In) In Service YES YES
Fn) Frame Format SF ESF
Fn) Frame Format SF ESF
Fn) Frame Format SF ESF
Fn) Frame Format SF ESF
Ln) Line Coding AMI AMI
Ln) Line Coding AMI AMI
Ln) Line Coding AMI AMI
Ln) Line Coding AMI AMI
Bn) Line Build Out 0db 0db
Bn) Line Build Out 0db 0db
Bn) Line Build Out 0db 0db
Bn) Line Build Out 0db 0db
NDn) Network Density NONE NONE
NDn) Network Density NONE NONE
NDn) Network Density NONE NONE
NDn) Network Density NONE NONE
NLn) Network Initiated Loop NO NO
NLn) Network Initiated Loop NO NO
NLn) Network Initiated Loop NO NO
NLn) Network Initiated Loop NO NO
An) Alarm Declare Time(sec) 0 0
An) Alarm Declare Time(sec) 0 0
An) Alarm Declare Time(sec) 0 0
An) Alarm Declare Time(sec) 0 0
DLn) FDL Enable NO NO
DLn) FDL Enable NO NO
DLn) FDL Enable NO NO
DLn) FDL Enable NO NO
PRM Enable NO NO
PRM Enable NO NO
PRM Enable NO NO
PRM Enable NO NO
En) Enable Inband/ISDN both dis both dis
En) Enable Inband/ISDN both dis both dis
En) Enable Inband/ISDN both dis both dis
En) Enable Inband/ISDN both dis both dis
Sn) Inband Timeslot 1 1
Sn) Inband Timeslot 1 1
Sn) Inband Timeslot 1 1
Sn) Inband Timeslot 1 1
F) FDL configuration
F) FDL configuration
F) FDL configuration
F) FDL configuration
T) Timing
T) Timing
T) Timing
T) Timing
X) Exit this screen
X) Exit this screen
X) Exit this screen
X) Exit this screen
A [0.0.0.204] [1,2] DIDCSU 2912 >
A [0.0.0.204] [1,2] DIDCSU 2912 >
A [0.0.0.204] [1,2] DIDCSU 2912 >
A [0.0.0.204] [1,2] DIDCSU 2912 >