DIDCSU 2912 Quick Set-Up

2-12

Verilink DIDCSU 2912 User Manual

NOTE: These procedures may not match your configuration. Use this

chapter as a guide for equipment installation. Chapter 4,

DIDCSU E1 Version”

has complete details on configuration of

the E1 mode.

Connect to Craft

Port

Connect the modular (RJ-11) end of the Craft cable (P/N 458-
102119-008) to the port labeled

LOCAL

on the front panel of the NCM

controller module. Connect the other end of the Craft cable to your
PC or terminal.

Terminal

Parameters

Set your terminal, or terminal program to:

19.2 kbit/s

8 data bits

no parity

one stop bit

no flow control

Logging On

1. Press E

NTER

. The pSH+> prompt is displayed. Type “craft”.

2. A password prompt appears. Initially there is no password,

press E

NTER

to display the NCM Main Menu.

If the NCM Main Menu display (

Figure 2-15)

shows the DIDCSU in

the proper shelf/slot position (letter A in slot 2), go to

Step 10

.