Sense level= 12, Dial mode= tone, Cpc detect= on – Skutch Electronics BA-1000-A Technical Reference Guide User Manual
Page 21: Dial tone hu= on, Talk limit= 12, Pause timeout=35, Voice trigger=02, Tt on time= 02

Version 6.XX
Page 21
Enter the level from
05
05
05
05
to
15
15
15
15
then press then
release
#
#
#
#
to go to the next option. You can press then release
~
~
~
~
to return to the
Total Calls
screen.
Sense Level= 12
This option lets you manually set the sensitivity level for
the system’s answer detect. CAUTION: This value should
NOT be adjusted unless instructed to by a Skutch Service
Technician.
Sense Level= 12
01 to 20 #=Next
Enter the level from
01
01
01
01
to
20
20
20
20
then press then
release
#
#
#
#
to go to return to the Total Calls screen. You can
press then release
~
~
~
~
to return to the
Total Calls
screen.
Dial Mode= Tone
This option allows you to select touch tone dialing or
pulse dialing. Some phone lines still only allow pulse dialing
for outbound calls; in these areas you can change the system to
pulse dial mode. The display looks as follows:
Dial Mode= Tone
1=Change #=Next
Press then release
1
1
1
1
to toggle between Tone and Pulse;
press then release
#
#
#
#
to go to the next option. You can press
then release
~
~
~
~
to return to the
Total Calls
screen.
CPC Detect= On
This option allows you to disable the system’s ability to
detect the CPC disconnect pulse sent by some telephone
companies. When set to On, the system will, on detecting a
CPC pulse, hang up on the current phone call and log it as a
Hang Up. When set to Off, it will ignore any CPC pulses sent.
The display will look as follows:
CPC Detect= On
1=Change #=Next
Press then release
1
1
1
1
to toggle between On and Off;
press then release
#
#
#
#
to go to the next option. You can press
then release
~
~
~
~
to return to the
Total Calls
screen.
Dial Tone HU= On
This option allows you to make the system hang up on any
caller when it detect a return Dial Tone during the message
record phase, when On. When set to Off, it will ignore any Dial
Tone received. The display will look as follows:
Dial Tone HU= On
1=Change #=Next
Press then release
1
1
1
1
to toggle between On and Off;
press then release
#
#
#
#
to go to the next option. You can press
then release
~
~
~
~
to return to the
Total Calls
screen.
Talk Limit= 12
This option tells the system how many seconds of
continuous talking it can accept, before it considers the call a
Recorded Message. For this option, 1 = 10 second. A setting of
25 is unlimited talk time. The display will look as follows:
Talk Limit= 12
01 to 25 #=Next
Enter from
01
01
01
01
to
25
25
25
25
then press then release
#
#
#
#
to go to the next option. You can press then release
~
~
~
~
to return to the
Total Calls
screen.
Pause Timeout=35
This option tells the system how many seconds of silence
it needs in order to stop recording and continue with the
outgoing message. For this option, 1 = .1 seconds. The display
will look as follows:
Pause Timeout=35
15 to 80 #=Next
Enter from
15
15
15
15
to
80
80
80
80
then press then release
#
#
#
#
to go to the next option. You can press then release
~
~
~
~
to return to the
Total Calls
screen.
Voice Trigger=02
This option tells the system how much time is needed to
trigger a valid voice response. If the caller talks less than this
setting, the system will not allow any alert trigger for this caller.
For this option, 1 = 1 second. The display will look as follows:
Voice Trigger=02
01 to 60 #=Next
Enter from
01
01
01
01
to
60
60
60
60
then press then release
#
#
#
#
to go to the next option. You can press then release
~
~
~
~
to return to the
Total Calls
screen.
TT On Time= 02
This option sets how long each touch tone, the system
dials, stays on. Some paging systems require the touch tones to
be longer so they can break the automated messages; this allows
you to increase that time. For this option, 1 = 1 second. The
display will look as follows:
TT On Time= 02
02 to 32 #=Next