EIA-232 Interface

7.3.3 Diagnostics – 3

Selection 3, Diagnostics, will allow users to open the LD5100's Diagnostic menu. This menu

is primarily used for advanced diagnostics and troubleshooting.

Figure 7.4 EIA-232 Diagnostics Menu

The options available on the Diagnostics Menu are described in Table 7.1.

Table 7.1 Diagnostic Menu Options

Option

Description

Cable Readings – 1

Selection 1 displays the current cable readings, including

both cable length and any present current leakage.

Set 4-20mA Output – 2

Selection 2 allows a user to manually set the 4-20mA

output to test its function.

Cable Relay On – 3

Selection 3 turns the internal cable test relay on.

Cable Relay Off – 4

Selection 4 turns the internal cable test relay off.

Output Relay K1 On – 5

Selection 5 turns the Leak relay on.

Output Relay K1 Off – 6

Selection 6 turns the Leak relay off.

Output Relay K2 On – 7

Selection 7 turns the Fault relay on.

Output Relay K2 Off – 8

Selection 8 turns the Fault relay off.