OpenEye CM-511 User Manual
Page 42
42
Alarm Type
There are two kinds of alarm types: Normal Open and Normal Close, which are illustrated as below.
Select an alarm type that corresponds with the alarm application.
Alarm Action
The alarm actions include PRESET, TOUR, AUTOSCAN and PATTERN functions. Select one of these
modes so that certain action will be executed when an alarm is triggered. Use the right direction key of the
control keyboard to select a particular action mode, and the items listed below will change in accordance
with your selected alarm action.
Preset Point
Select a preset point where the dome should go when an alarm pin is triggered. The preset point(s) should
be set prior either in the PRESET setup menu or through the keyboard.
TOUR LINE - Select a Tour line that the dome camera should execute when an alarm pin is triggered. The
Tour line(s) should be defined prior either in the TOUR setup menu or through the keyboard.
AUTOSCAN LINE - Select an Auto Scan line that the dome camera should execute when an alarm pin is
triggered. The Auto Scan line(s) should be defined prior either in the AUTOSCAN setup menu or through
the keyboard.
PATTERN LINE - Select a Pattern line that the dome camera should execute when an alarm pin is
triggered. The Pattern lines should be defined prior either in the PATTERN setup menu or through the
keyboard.
Dwell Time
The DWELL TIME is duration of executing an alarm action. If select the PRESET mode, when alarm takes
place, the dome will go to the selected preset position and stay there for a user-defined period of time
(1~127 seconds / ALWAYS). If select other modes (TOUR/AUTOSCAN/ PATTERN), the dome will keep
executing the selected mode (DWELL TIME: ALWAYS) until alarm condition is released or users rotate
the dome.
Note
The dwell time is only adjustable when selecting Preset as the alarm action.
Exit
Exit the ALARM SETTING menu and go back to the MAIN PAGE 3 to carry on setup of WDR function
Normal Open
Alarm In
Normal Close
Alarm In