OpenEye CM-511 Quick Start User Manual
Cm-511 | high speed dome camera quick guide
AC 24V
GND
AC 24V
Power Input
Video Output
Alarm Cable
RS-485
DVR/Keyboard (2-wire)
DVR/Keyboard (4-wire)
RS-485 Setting
Half-duplex
Full-duplex
Communication Switch
SW 1
RS-485 Setting
SW 2
SW 3
Termination
SW 4
Line Lock
SW 5
System Initialization
SW 6
Reserved
This quick operation guide is a quick reference for users to install and operate the dome camera and only provides
basic information on the camera’s settings and operation. Before attempting to connect, confi gure and operate the
dome camera, please read the installation guide and the user manual thoroughly.
System Confi guration
Dome Camera
Optical Cover
Data Cable (AC24V)
Screws
Lubricant
Quick Guide
Installation & User Manuals
•
•
•
•
•
•
•
Box Contents
ON
OFF
1 C A M E R A 75 T E R M 16
Video
Video
Video
Video
Video
RS-485
RS-485
RS-485
RS-485
RS-485
Control Keyboard
Repeater
Dome Camera
Call Monitor
Main Monitor
Switch/Quad/MUX/DVR
Dome Camera
Dome Camera
Dome Switch Defi nition
A
Communication Switch
B
Dome ID Switch
C
Dome Control Protocol Switch
D
22-Pin Connector
E
ISP Connector (for FW upgrade)
Communication Switch Setting
The table below shows the function of each switch within the Communication Switch on the dome back plate.
Dome Control Protocol Setting
Refer to the table below and select a protocol and baud rate appropriate for your installation, based on the control
device. Adjust the Protocol Switch on the dome camera back plate. For example, the protocol switch should be set as
below if you are using the Pelco D protocol, with the switch number of 01 and a baud rate of 2400.
Decimal Digit
Single Digit
Dome ID Setting
Change the dome ID if there is more than one dome on the same installation. To change the dome camera ID, turn
each arrow of the ID switch to the desired number respectively. For example, if the dome ID is 123, the ID switch
should be set as below. The default dome ID is 001.
Centesimal Digit
Decimal Digit
Single Digit
Switch No.
Protocol
Baud Rate
00
VCL
9600
01
Pelco D
2400
02
Pelco P
4800
04
Chiper
9600
05
Philips
9600
07
OPTIX 3*
9600
08
AD422
4800
09
DM P
9600
11
Pelco D
4800
12
Pelco D
9600
13
Pelco P
2600
14
Pelco P
9600
15
JVC
9600
21
Kalatel-485
9600
22
Kalatel-422
4800
22-Pin Connector Defi nition
When cabling, refer to the fi gure and table below for information about the defi nition of each pin on the data cable.
22-Pin Connection
Pin
Defi nition
Cable
1
AC 24-1/DC (+)
20AWG/18AWG
2
ALM NC
3
AC 24-2/DC (-)
20AWG/18AWG
4
ALM NO
5
FG
20AWG/18AWG
6
ALM COM
7
T+
24AWG
8
R-
9
T-
10
R+
11
ISOG
12
ALM-1
13
ALM-3
14
ALM-2
15
ALM-4
16
ALM-5
17
ALM-6
18
ALM-7
19
ALM-8
20
ALM GND
21
VGND
20AWG
22
Video
Data Cable and Connector Defi nition
The data cable supplied with the dome camera is an AC 24V.
Refer to the fi gures below for the defi nition of each connector before wiring.
Grounding Recommendation
A
B
C
D
E
* Default Protocol Setting
The GND (ground) wire must be directly connected to the middle pin of the AC24V power connector. Failure to connect
the ground can cause damage and failure of the camera.
If the connection of the GND wire causes video noise, use a video isolator. This is only necessary in some situations.
AC 24V
VIDEO OUT
Must be
connected
to ground
(GND)
Video
Isolator
Optional
AC 24V
Adapter
3 pins terminal block
VIDEO OUT
RS-485
Alarm I/O
2
3
4
Power Wire Length Specifi cations
CM-511 | High Speed Dome Camera Quick Guide
AC 24V Data/Alarm Cable
Note
The CM-511 outdoor dome camera only supports AC 24V
Note
OpenEye recommends Category 5 or 6 Twisted Pair Cable
for the RS-485 wire.
www.openeye.net
Wire Gauge
Maximum Distance
22
27 feet
20
44 feet
18
69 feet
16
110 feet
Wire Gauge
Maximum Distance
14
175 feet
12
279 feet
10
444 feet