0x75 - transmit envelope - variable length – NavCom LAND-PAK Rev.N User Manual
Page 85
Technical Reference Manual Rev. N
Blk = All;
Blu = IOP w/Internal Radio
;
Red = IOP & LBM
;
Grn = Engine only
83
0x75 - Transmit Envelope - Variable Length
This message is used to address a message to a specific NCT integrated receiver on an
available network (i.e. turn off RTK base function on a distant unit).
Record
Usage
Command - Yes
Response - No
Input: sets the remote internal radio operation;
Ref
Message Field Description
Data Type Units
Range
Scale
Byte
Count
STX
02
(hex)
U08
1
PRA1 99 (hex)
U08
1
PRA2 66 (hex)
U08
1
ID
75 (hex)
U08
1
Length 0x0xxx
U16
2
W1
Reserved
U08
1
W2
HOP count - Number of HOPS
U08
1
W3
To Address: Ghost ID of Unit
(Radio ID)
Unit uses internal block if
Address matches (W3)
Otherwise, Slave Rebroadcasts
message and Increments
HOP count, if HOP equals
0 (Master will rebroadcast with
HOP count at 0 or 1, all
messages not addressed to it).
All Units will match to broadcast
ID (0xc350, decimal
50000)
U16
2
W4
From Address: Ghost ID of the Unit
to respond to
U16
2
W5
Internal Block
B1: Command ID
B2: Msg. Len.
B3: W1
Bn:
Wm
end of internal
message
Checksum
U08
U16
…
…
U08
1
2
…
…
1
CKSM Checksum
U08
1
ETX
03
(hex)
U08