0xc9 - LBM Serial Port Control - 7 bytes
NavCom receivers that contain an internal L-band (StarFire, aka: LBM) module do not support
this message. (The internal baud rate is fixed at 19200 for these receivers).
Record
Usage
Command - Yes
Response - Yes
Input: Set the LBM data port assignment and baud rate;
Output: reports LBM data port settings
Ref
Message Field Description
Data
Type
Units
Range Scale
Byte
Count
STX
02
(hex)
U08
1
PRA1 99 (hex)
U08
1
PRA2 66 (hex)
U08
1
ID
c9
(hex)
U08
1
Length 0x0007
U16
2
W1
Command Action
B1=0: Do not store in NVRAM
1: Store in NVRAM
B2=0: Do not use ACK/NAK
1: Use ACK/NAK
B3=0: Use Commanded Values
1: Use Default values
U08
1
W2
0xff - Upon receipt, Value contains Physical Port
used
U08
1
W3
Port Setup
Reserved
B0: Not Used
Baud Rate
B1=0, B2=0, B3=0:
1200
B1=1, B2=0, B3=0:
2400
B1=0, B2=1, B3=0:
4800
B1=1, B2=1, B3=0:
9600
B1=0, B2=0, B3=1:
19200 (default)
B1=1, B2=0, B3=1:
38400
B1=0, B2=1, B3=1:
57600
not
supported:
B1=1, B2=1, B3=1:
115200
Parity Selection
B4=0,B5=0:
NONE (default)
B4=1,B5=0:
ODD
B4=1,B5=1:
EVEN
Reserved
B7-B6: Not Used
U08 bps
1200 –
57600
1
CKSM Checksum
U08
1
ETX
03
(hex)
U08
1
1: Configured for 8-bit word length and 1 stop bit.
2: For multiple command actions, the bits in W1 may be OR’ed.
3: LBM is configured as DTE.
4: If ACK/NAK is selected, and the input sentence is accepted, the ACK will be
put out at the new settings.
5: Present LBM oscillator (20 MHz) will not support 115200 baud.