beautypg.com

Microcom 438 User Manual

Page 99

background image

Printer Commands

Chapter 5

5-52

438 Operator’s Manual - 880052-0100

^A

^D

COMMAND

X

155 Set Feed Speed:

This command sets the feed speed that is used for the D153 and D154
commands.


0

8.0 ips (inches per second)

1

7.5 ips

2

7.0 ips

3

6.5 ips

4

6.0 ips

5

5.5 ips

6

5.0 ips

7

4.5 ips

8

4.0 ips

9

3.5 ips

10

3.0 ips

11

2.5 ips

12

2.0 ips

13

1.5 ips

14

1.0 ips

15

0.5 ips


X

156 Set Non-stick Time Interval:

This command is used to set the time interval for the Non-stick TOF mode
(D26 position 8) used to help alleviate the media adhering to the platen roller.
The value for X represents the number of seconds that the printer will execute
the Non-stick TOF operation. The default setting is 14400 or 4 hours. The
valid range is from 2 to 65536. This command is volatile and gets reset to the
default setting after power cycles and/or command reset conditions. The
^A1^D145 command may be used to observe the current setting and the
elapsed time counter.


X

157 Takeup Motor Run Time:

The D157 command is used with optional software that controls a DC Takeup
motor instead of a cutter motor. The value for X represents how long the
takeup motor will run, in milliseconds, after printing has stopped. This
command is a volatile command with a default of 0. The ^A1^D145 command
lists the current setting under the Post Takeup Time.


0 157 0
1

25 25 msec

2

50

3

75

4

100

5

125

6

150

7

175

8

200

9

225

10

250

This manual is related to the following products: