Printer Commands
Chapter 5
5-52
438 Operator’s Manual - 880052-0100
^A
^D
COMMAND
X
155 Set Feed Speed:
This command sets the feed speed that is used for the D153 and D154
commands.
0
8.0 ips (inches per second)
1
7.5 ips
2
7.0 ips
3
6.5 ips
4
6.0 ips
5
5.5 ips
6
5.0 ips
7
4.5 ips
8
4.0 ips
9
3.5 ips
10
3.0 ips
11
2.5 ips
12
2.0 ips
13
1.5 ips
14
1.0 ips
15
0.5 ips
X
156 Set Non-stick Time Interval:
This command is used to set the time interval for the Non-stick TOF mode
(D26 position 8) used to help alleviate the media adhering to the platen roller.
The value for X represents the number of seconds that the printer will execute
the Non-stick TOF operation. The default setting is 14400 or 4 hours. The
valid range is from 2 to 65536. This command is volatile and gets reset to the
default setting after power cycles and/or command reset conditions. The
^A1^D145 command may be used to observe the current setting and the
elapsed time counter.
X
157 Takeup Motor Run Time:
The D157 command is used with optional software that controls a DC Takeup
motor instead of a cutter motor. The value for X represents how long the
takeup motor will run, in milliseconds, after printing has stopped. This
command is a volatile command with a default of 0. The ^A1^D145 command
lists the current setting under the Post Takeup Time.
0 157 0
1
25 25 msec
2
50
3
75
4
100
5
125
6
150
7
175
8
200
9
225
10
250