Microcom 438 User Manual
Page 200
438 Operator’s Manual - 880052-0100
13-17
^A
^D
COMMAND
XX
120 AutoLoad Delay Selection: The AutoLoad Delay is the amount of time, in
Milliseconds, that the printer waits after detecting that media has been put into
the printer before it starts feeding it in.
121 Top Of Form Command: This command causes the printer to perform a
Top-of-Form. This command requires a LPD sensor to be installed on the
printer.
122 Display Available FLASH memory: This command is used to display the
amount of available flash memory for file storage.
XX
123 Set TOF Retract Distance: Sets the distance that the printer will retract when
performing a TOF operation. The retraction distance range is from 1 to 900
with the units being in dots or pixels.
XX
124 Stock Out Threshold: Sets the stock out threshold
xxyy 127 Save FONTS to RAM: This command is used to load or save fonts to the
volatile RAM memory. Refer to Chapter 7 for more detail.
X
129 Auto Set Threshold: This command automatically determines and sets the
nonvolatile threshold for proper registration.
0
Automatically sets the transmissive threshold value.
1
Automatically sets the reflective threshold value.
XX
130 Save a FORMAT to FLASH: This command is used to save an LDS format
to non-volatile flash memory. The ^A value is used to indicate the memory
slot location into which the format will be saved. Formats are saved in a
separate area of flash than the fonts and graphics so the memory slots for the
formats are independent from the fonts and graphic memory slots. The valid
range of memory slots is from 1 to 128.
XX
131 Delete a FORMAT from FLASH: Used to delete a format that has been
stored in flash memory. The ^A value is used to specify the memory slot of
the stored format that will be deleted.
xxyy 133 Save Compressed GRAPHICS to FLASH: This command is used to save
graphic’s into non-volatile flash memory. The ^Axxyy^D133 command is
placed at the beginning of a graphic download and instructs the printer to save
the following data as a graphic file. The
printer the end of file download and acts as the command terminator.
xx
The number of additional 64KB sectors needed to save the graphic file.
yy
The memory slot location of the graphic being saved; CGN # (1-255)
XX
134 Delete a GRAPHIC from FLASH: Instructs the to delete a graphics from flash
memory. Issuing a “0” for the ^A value causing the printer to delete all flash
graphics. The ^A value is used to select the memory slot or CGN # that will be
deleted. The valid values for Axx are 0 to 255.