Bar Codes
Chapter 8
8-12
438 Operator’s Manual - 880052-0100
The following format is used to generate a PDF-417 bar code:
^D77
:Text Data^\
Number_of_Rows
Number_of_Columns
Rotation
ECC_Percent
ECC_Level
Aspect_Ratio
This format is then followed by the placement instructions and text placeholder.
:Text Data^\
This parameter is where the desired data is placed and must be terminated with the “^\[“ or
0x1C control code. The text data may include carriage returns and other control codes.
Number of Rows
The PDF-417 symbology may have as few as 3 or as many as 90 rows with a default setting
of 90. A carriage return character must be used to terminate this field.
Number of Columns
symbology. The PDF-417 symbology may have 1 to 30 columns with a default setting of 30.
A carriage return character must be used to terminate this field.
Rotation
increments. The valid arguments for this parameter would be 0, 90, 180 or 270 with the
default being set to 0. A carriage return character must be used to terminate this field.
ECC_Percent
Error Correction Control (ECC) of the PDF-417 symbology. This parameter has to be set to
0 if the ECC# method is desired. The default ECC% is set to 0. A carriage return character
must be used to terminate this field.
ECC_Level
symbology with a default value set to 0. This parameter can only be used if the ECC%
parameter is set to 0. Refer to Table 17 for the valid ECC_Level values and their equivalent
correction code words. A carriage return character must be used to terminate this field.
Aspect Ratio
entered in ratio format (height: width) and has a default value of 2:1. A carriage return