Microcom 438 User Manual
Page 192
438 Operator’s Manual - 880052-0100
13-9
^AB ^D
COMMAND
26
Software Bank Switch #6: A non-volatile command used to set the various
functions identified below.
^AB12345678
Position:
1
1 = Enable >TRAY FULL< response; 0 = Enable Test Pattern
2
1 = Enable STL Emulation; 0 = Disable
3
1 = Enable Pre-Stock Out Feature; 0 = Disable
4
1 = Enable >STOCK NOT LOADED< response; 0 = Disable
5
1 = Enable 48-466 Compatibility mode; 0 = Disable
6
1 = General Purpose I/O Enable; 0 = Custom I/O Enable
7
1 = Enable Takeup Control; 0 = Enable Cutter Control
8
1 = Enable Nonstick TOF Mode; 0 = Disable
27
Software Bank Switch #7: A non-volatile command used to set the various
functions identified below.
^AB12345678
Position:
123
Select STL Stock Class:
100 Standard Ticket
010 Cinema Ticket
001 Wristbands
456
Select STL Stock Width (Inches):
000 1.00
100 1.328
010 2.00
110 2.125
001 2.50
101 2.75
011 3.25
111 4.00
7
1 = Disable System Parameter Saving; 0 = Enable
8
1 = Enable Finish Mode; 0 = Disable