438 Operator’s Manual - 880052-0100
13-7
^AB ^D
COMMAND
21
Software Bank Switch #1: A non-volatile command used to set the various
functions identified below.
^AB12345678
Position:
12
Enquiry Responses:
00 = Control Codes
10 = Text Equivalent
3
1 = Ignore Control Codes; 0 = Accept
4
1 = Odd Parity; 0 = Even Parity
5
1 = Disable Parity (NONE); 0 = Enable Parity
6
1 = Enable Echo; 0 = Disable
7
1 = 8 Data Bits; 0 = 7 Data Bits
8
1 = Enable XON/XOFF; 0 = Disable
22
Software Bank Switch #2: A non-volatile command used to set the various
functions identified below.
^AB12345678
Position:
1
1 = Enable Clear Text; 0 = Disable
2
1 = Enable >RESTARTED< Response; 0 = Disable
3
1 = Disable Button; 0 = Enable
4
1 = Enable Print Repetition; 0 = Enable Form Feed
5
1 = Use Saved Format File; 0 = ROM Format
678
Power-up / ROM Format Selection:
000 = No Power-up Format
001 = ROM or Saved Format File 1
010 = ROM or Saved Format File 2
011 = ROM or Saved Format File 3
100 = ROM or Saved Format File 4
101 = ROM or Saved Format File 5
110 = ROM or Saved Format File 6
111 = ROM or Saved Format File 7
23
Software Bank Switch #3: A non-volatile command used to set the various
functions identified below.
^AB12345678
Position:
1
1 = Disable Extended ASCII; 0 = Enable
2
1 = Active LOW for >INPUT1<; 0 = Active HIGH
3
1 = Send Enquiry Response after Print; 0 = Disable
4
1 = Active LOW for >INPUT2<; 0 = Active HIGH
5
1 = Disable use of | for control; 0 = Enable
6
1 = Disable use of ^ for control; 0 = Enable
7
1 = Enable Binary Compression; 0 = Disable
8
1 = Enable Detect Blackline on Power-up; 0 = Disable