Specifications, Specifications 9, Physical – Measurement Computing DBK70 User Manual
Page 97: Environmental, Electrical, Analog outputs, Software requirements

DBK70 User’s Manual
948796
Specifications 9-1
Specifications
9
Physical
Dimensions: 280mm W x 216mm D x 44mm H (11” x 8” x 1.75”)
Weight: 1.1kg (2.5lbs)
Connectors:
Serial
configuration:
DB9
female
Network
port:
HD44
female
Direct parameter output ports: DB25 male
Data acquisition cascade port: DB37 male
Power:
DIN5
female
Environmental
Operating temperature: -20°C to +70°C
Electrical
Power consumption: 0.11A @ 12V
Supply voltage: 10 to 30VDC
Analog Outputs
Output resolution: 16 bits, auto dependent
Integral Non-Linearity: +4 bits max
Differential Non-Linearity: +2 bits max
Gain temperature coefficient: 10 ppm / °C max
Settling time (0-5V): 50uS + 0.01 max
Output offset error: 1mV max
Output gain error: 0.015% max
Rise time (10% o 90%) 5V: 25uS max
Offset temperature coefficient: 10uV / °C max
Time stability: 50 ppm / month
Maximum output capacitance: 5000pF
Output short circuit: +15 mA typical
Output load resistance:
2 outputs at 5V: 1K
Ω min
All outputs at 5V: 10K
Ω min
Type of outputs: Single ended
Voltage range: 0.0V to 5.0V
Isolation range: +30V
Software Requirements
Operating system: Windows 98, Me, 2000, and XP.
Driver compatibility (using the driver of the data acquisition product):
Windows 98, Me, 2000, XP, C++, VB, Visual Basic, LabView, DASYLab.