Measurement Computing DBK70 User Manual
Page 60

5-30
919092
PidPRO & PidPRO+
Message
– Similar to “Msg 1 and Msg 2” in Detailed View, page 5-21.
This field specifies a message that is to be sent by the DBK70 on the vehicle’s data bus at the rate specified
by Update Rate parameter.
The codes to be used for the Message field are hexadecimal byte values (i.e., 00 to FF). The maximum
length is dependent on the type of vehicle data bus (e.g., 12 bytes for J1850) to be used.
Request messages are used to obtain data when the data to be processed by an output channel is not
normally available on the vehicle’s data bus but can be obtained by sending a request for it.
To issue one message, make sure there are no spaces in your string of hex characters. To issue more than
one message packet, insert one space between the independent groups of hex characters.
Filter
– See “
Filter
” in Detailed View, page 5-22.
Timeout
– See “
If no match in ___mS
” in Detailed View, page 5-22.
Default Value
– See “
set chan to __µV
” in Detailed View, page 5-22.
Analog to Engineering Units Conversion
– See “
Analog to Engineering Units Conversion
” in Detailed View, page 5-27.