Controls and indicators -2, Ht4001 power supply front panel -2, Ht4001 power supply rear panel control -2 – Hypertherm HT4001 Plasma Arc Cutting System User Manual

Page 93: Controls and indicators

background image

OPERATION

11-96

5-2

HT4001

Instruction Manual

Controls and Indicators

HT4001 Power Supply Front Panel (Fig. 5-1)

POWER

AC Indicator

Indicator illuminates when power up is complete.

• DC Indicator

Illuminates when main contactor closes, indicating DC power is being supplied to the torch.

STATUS

• RHF DOOR LED

When illuminated, indicates that one of the door interlock switches in the RHF console is disengaged. (RHF
console door is open)

• TRANSFORMER LED

When illuminated, indicates that either the power supply main transformer or one of the choppers is
operating in an unacceptable temperature range.

• COOLING WATER LED

When illuminated, indicates that the coolant flow to the electrode is inadequate.

• PLASMA GAS LED

When illuminated, indicates that the plasma gas pressure is inadequate.

HT4001 Power Supply Rear Panel Control (Fig. 5-2)

POWER

• UP Position (I)

In this position, AC is sent to the control transformer, turning the power supply on.

• DOWN Position (O)

In this position, AC is cut off to the control transformer, turning the power supply off.