Initial height sensing connections -32, Initial height sensing connections, Installation – Hypertherm HT4001 Plasma Arc Cutting System User Manual
Page 85
INSTALLATION
2-95
4-32
HT4001
Instruction Manual
Initial Height Sensing Connections
See page 4-18 for IHS connection to power supply.
Air Supply Hose – IHS Module to Air Supply
The customer must supply the 20 psig regulated shop air and the air hose. A #4 swivel fitting (015259) comes
with the IHS console assembly.
Air Hose Assembly – IHS Module to Inductive Sensor Air Cylinder
The 40-foot air hose is a component of the IHS leads packages – see page 7-47.
Inductive IHS Torch Mounting Assembly
The two inductive probes come as part of the IHS torch mounting subassembly – see page 7-47.
IHS Sensor Cables - IHS Module to IHS Probes
The 40-foot sensor cables are components of the IHS leads packages – see page 7-47.
FUNCTION
PIN
COLOR
Power (+15 VDC)
A
Brown
Common
B
Blue
Signal
C
Black
Part No.
005074
FUNCTION
IHS END
COLOR
PROBE END
Power (+15 VDC)
4
Red
A
Common
2
Black
B
Signal
1
Clear
C
Shield
3
Braid
25
26
27
28
1
3
2
4
B
A
C
1
3
2
4
B
A
C
Part No.
Length
024144
40 ft (12 m)
Part No.
Length
023888
2 ft (.6 m)
023869
40 ft (12 m)
Part No.
Length
023889
2 ft (.6 m)
023870
40 ft (12 m)
8X2
8X4
8X3
8X5