Initial Height Sensing Connections

See page 4-18 for IHS connection to power supply.

Air Supply Hose – IHS Module to Air Supply
The customer must supply the 20 psig regulated shop air and the air hose. A #4 swivel fitting (015259) comes
with the IHS console assembly.

Air Hose Assembly – IHS Module to Inductive Sensor Air Cylinder
The 40-foot air hose is a component of the IHS leads packages – see page 7-47.

Inductive IHS Torch Mounting Assembly
The two inductive probes come as part of the IHS torch mounting subassembly – see page 7-47.

IHS Sensor Cables - IHS Module to IHS Probes
The 40-foot sensor cables are components of the IHS leads packages – see page 7-47.

FUNCTION

PIN

COLOR

Power (+15 VDC)

A

Brown

Common

B

Blue

Signal

C

Black

Part No.

005074

FUNCTION

IHS END

COLOR

PROBE END

Power (+15 VDC)

4

Red

A

Common

2

Black

B

Signal

1

Clear

C

Shield

3

Braid

25

26

27

28

1

3

2

4

B

A

C

1

3

2

4

B

A

C

Part No.

Length

024144

40 ft (12 m)

Part No.

Length

023888

2 ft (.6 m)

023869

40 ft (12 m)

Part No.

Length

023889

2 ft (.6 m)

023870

40 ft (12 m)

8X2

8X4

8X3

8X5