beautypg.com

Nitrogen, Ht4001 without slave, Pac620 torch – beveling consumables – Hypertherm HT4001 Plasma Arc Cutting System User Manual

Page 118: Mild steel or stainless steel – nitrogen plasma

background image

11-96

HT4001

Instruction Manual

5-27

Notes:

• Minimum N

2

inlet supply pressure remains at one setting of 150 psi (10.3 bar) for all material thickness.

• Water chiller pump outlet pressure remains between 175-185 psi (12-12.8 bar) for all material thickness.
• N

2

flow rate at full scale is 374 scfh (176 l/min) @ 150 psi (10.3 bar) inlet pressure.

• Set initial torch height (before piercing) to approximately twice the Torch Standoff distance for the material you are

cutting.
Note: If arc does not transfer when set at twice the torch standoff (in the case of thick metal being cut at high
current), gradually lower the initial height of the torch until transfer occurs.

HT4001 without Slave

PAC620 Torch – Beveling Consumables

Mild Steel or Stainless Steel – Nitrogen Plasma

Retaining Cap

120390 (Vect)

120391 (Vesp)

Nozzle

120386

(.120 in/3 mm)

120387

(.166 in/4.2 mm)

Swirl Ring

020039 (cw)

020042 (ccw)

Electrode

020968

Water Tube – O

2

Bevel

020991

120470 – CE (Vect)
120471 – CE (Vesp)

E

N

G

L

I

S

H

M

E

T

R

I

C

Test Preflow

Rate

Test Cut Flow

Rate

(N

2

)

(N

2

)

(in)

(mm)

(%)

(%)

(%)

(in)

(mm)

(ipm)

(mm/min)

.035

.889

30

30

45

125

240

1/8

3

425

10800

.075

1.91

30

30

45

130

240

1/8

3

285

7240

1/8

3.18

30

30

45

145

240

3/16

5

190

4830

1/4

6.35

30

30

45

155

240

3/16

5

145

3680

1/8

3.18

45

45

62

125

300

1/4

6

170

4320

1/4

6.35

45

45

62

135

340

1/4

6

140

3560

3/8

9.53

45

45

62

145

360

1/4

6

120

3050

1/2

12.7

45

45

62

145

380

5/16

8

90

2290

3/4

19.1

45

45

62

150

400

5/16

8

50

1270

1

25.4

45

45

62

155

400

3/8

10

30

760

.166"

400A max.

Arc

Current

(A)

Torch

Standoff

Travel Speed

.120"

260A max.

Nozzle

Material

Thickness

Water Flow

Setting

Arc Volts

(V)

Test Preflow

Rate

Test Cut Flow

Rate

(N

2

)

(N

2

)

(mm)

(%)

(%)

(%)

(mm)

(mm/min)

3 mm

260A max.

6

30

30

45

155

240

5

3800

6

45

45

62

135

340

6

3640

8

45

45

62

140

360

6

3300

10

45

45

62

145

360

6

2930

12

45

45

62

145

380

6-7

2450

15

45

45

62

150

400

8

1900

20

45

45

62

150

400

8

1200

25

45

45

62

155

400

10

790

Arc

Current

(A)

Torch Standoff

Travel Speed

4.2 mm

400A max.

Nozzle

Material

Thickness

Water Flow

Setting

Arc Volts

(V)