Nitrogen, Ht4001 without slave, Pac620 torch – standard consumables – Hypertherm HT4001 Plasma Arc Cutting System User Manual
Page 114: Stainless steel – nitrogen plasma

11-96
HT4001
Instruction Manual
5-23
Notes:
• Minimum N
2
inlet supply pressure remains at one setting of 150 psi (10.3 bar) for all material thickness.
• Water chiller pump outlet pressure remains between 175-185 psi (12-12.8 bar) for all material thickness.
• N
2
flow rate at full scale is 374 scfh (176 l/min) @ 150 psi (10.3 bar) inlet pressure.
• Set initial torch height (before piercing) to approximately twice the Torch Standoff distance for the material you are
cutting.
Note: If arc does not transfer when set at twice the torch standoff (in the case of thick metal being cut at high
current), gradually lower the initial height of the torch until transfer occurs.
HT4001 without Slave
PAC620 Torch – Standard Consumables
Stainless Steel – Nitrogen Plasma
Retaining Cap
020579 (Vect)
020246 (Vesp)
Nozzle
020089
(.120 in/3 mm)
020084
(.166 in/4.2 mm)
Swirl Ring
020039 (cw)
020042 (ccw)
Electrode
020082
Water Tube – Standard
020990
120466 – CE (Vect)
120467 – CE (Vesp)
E
N
G
L
I
S
H
M
E
T
R
I
C
Test Preflow
Rate
Test Cut Flow
Rate
(N
2
)
(N
2
)
(in)
(mm)
(%)
(%)
(%)
(in)
(mm)
(ipm)
(mm/min)
.035
.889
30
30
45
125
260
1/8
3
450
11430
.075
1.91
30
30
45
130
260
1/8
3
300
7620
1/8
3.18
30
30
45
135
260
1/8
3
200
5080
1/4
6.35
30
30
45
145
260
1/8
3
150
3810
3/8
9.53
45
45
62
150
380
3/16
5
125
3170
1/2
12.7
45
45
62
155
400
3/16
5
100
2540
3/4
19.1
45
45
62
160
400
3/16
5
50
1270
1
25.4
45
45
62
165
400
1/4
6
30
760
1-1/2
38.1
45
45
62
185
400
1/4
6
20
510
2
50.8
45
45
62
200
400
1/4
6
12
300
.166"
400A max.
Arc
Current
(A)
Torch
Standoff
Travel Speed
.120"
260A max.
Nozzle
Material
Thickness
Water Flow
Setting
Arc Volts
(V)
Test Preflow
Rate
Test Cut Flow
Rate
(N
2
)
(N
2
)
(mm)
(%)
(%)
(%)
(mm)
(mm/min)
3 mm
260A max.
6
30
30
45
145
260
3
3950
10
45
45
62
150
380
5
3070
12
45
45
62
155
400
5
2680
15
45
45
62
160
400
5
2080
20
45
45
62
160
400
5-6
1200
25
45
45
62
165
400
6
790
35
45
45
62
180
400
6
570
50
45
45
62
200
400
6
310
Arc
Current
(A)
Torch Standoff
Travel Speed
4.2 mm
400A max.
Nozzle
Material
Thickness
Water Flow
Setting
Arc Volts
(V)